Search
View Cart     Home


















































































































































































Internal Workings & Identification
Four Chamber (RA-18, 22 & 28)
 
 
 
 
 
LEGEND
 
1:Heating Element #1 ••••• 2: Heating Element #2 •••••3:Heating Element #3
4:Heating Element #4 ••••• 5:Inlet Water Tube ••••• 6:Level Detect Screw
7:Level Detect Screw ••••• 8:Outlet Water Tube ••••• 9: Printed Circuit Board
10:Transformer ••••• 11:Heating Element Relays (8) •••••12:Audible Speaker
13:Output Temperature Control •••••14:Microprocessor Control Chip
15:Blue Button; Activates Audible ••••• 16:Terminal Spades for Leak Detect Wires
17:Triacs (4) ••••• 18:Triac Mounting Blocks to Heat Sink (4)
19:Copper Heat Sink Tube
 
L1:Power Connection Lugs (208 — 240 VAC)
L2:Power Connection Lugs (208 — 240 VAC)
H. Limit : High Temperature Limit Switches (2)
TH-IN : Inlet Temperature Sensor
TH-1 : Chamber Temperature Sensor #1
TH-2 : Chamber Temperature Sensor #2
TH-3 : Chamber Temperature Sensor #3
TH-4 : Chamber Temperature Sensor #4